High Frequency On line UPS
|
1KVA~3KVA ( IP/OP: 110/115/120VAC 50/60Hz) |
Application
Servers, Data-Center Critical network devices, Sensitive electronic equipment, Telecom...
Key Features
- True on-line double conversion technology with advanced microprocessor control
- Wide input voltage range
- Zero transfer time
- Protection against all type of power problems
- Self test while start of the UPS
- Site wiring fault warning
- On-battery power-on function
- Smart RS232 communication interface
- Intelligent slot available
- Sealed lead-acid, maintenance free battery
- tieds UPS, UPS battery backup
Technical Specifications:
|
| MODEL |
. |
UG1K |
UGIK(XL) |
UG2K |
UG2K(XL) |
UG3K |
UG3K(XL) |
| CAPACITY |
VA/W |
1000VA/700W |
2000VA/1400W |
3000VA/2100W |
| INPUT |
Phase |
Single Phase with Ground |
Frequency Range |
50Hz: 46~54Hz / 60Hz : 56~64Hz |
Power Factor |
>=0.95 |
Acceptable Voltage |
60~138 Vac |
Voltage Range |
Base on load percentage (100%-70% / 70%-60% / 60%-50% / 50%-40% / 40% - 0%) |
Line Low Transfer |
80VAC/70VAC/70VAC/60VAC/60VAC |
Line Low Comeback |
85VAC/85VAC/75VAC/75VAC/65VAC |
Line High Transfer |
138VAC |
Line High Comeback |
133VAC |
| OUTPUT |
Phase |
Single |
Voltage |
110VAC/115VAC/120VAC |
Voltage Regulation |
± 2% |
Power Factor |
0.7 / 0.8 |
Frequency |
50Hz : 46~54Hz / 60Hz : 56~64Hz |
( Synchronized Range) |
Frequency ( Battery Mode) |
50/60Hz / ± 0.2 Hz |
Current Crest Ratio |
03:01 |
Harmonic Distortion |
≦5% THD ( Linear Load) / |
≦10% THD ( Non-Linear Load) |
Output Waveform |
Pure Sinewave |
| EFFICIENCY |
To AC Mode |
85% |
83% |
86% |
To Battery Mode |
83% |
82% |
83% |
| BATTERY |
Battery Type |
12V/7.2Ah |
Depending on the capacity |
12V/7.2Ah |
Depending on the capacity |
12V/7.2AH |
Depending on the capacity |
Numbers of Batteries |
3 |
of external |
8 |
of external batteries |
8 |
of external batteries |
Backup Time (Full Load) |
>5 minutes |
batteries |
>9 minutes |
|
>5 minutes |
|
Recharge Time |
8 hours to 90% |
|
8 hours to 90% |
|
8 hours to 90% |
|
Charging Current (Max.) |
1.0A |
7.8A |
1.0A |
7.8A |
1.0A |
7.8A |
Charging Voltage |
41.1Vdc / ±0.6V |
110Vdc / ±0.4V |
110Vdc / ±0.4V |
External Battery Type |
N/A |
12V / 7.2 AH * 6 |
N/A |
12V / 7.2 AH *8 |
N/A |
12V / 7.2 AH * 8 |
| TRANSFER TIME |
AC to DC |
Zero |
Inverter to Bypass |
2.5ms (Typical ) |
Zero |
| INDICATOR |
LCD |
UPS status,I/P&O/P voltage&frequency,Battery voltage,Battery capacity,Loading%,Temperature,History record |
LED |
Normal(green),Warning(yellow),Fault(red)LED |
| AUDIBLE ALARM |
Battery Mode |
Sounding every 4 seconds |
Low Battery |
Sounding every second |
Overload |
Sounding twice every second |
Fault |
Continuously Sounding |
| DIMENSION |
UPS Case |
400x145x220 |
465x145x220 |
465x192x340 |
D x W x H (mm) |
Battery Case |
N/A |
400x145x220 |
N/A |
465x145x220 |
N/A |
465x192x340 |
D x W x H (mm) |
| WEIGHT |
Net Weight(kgs) |
13(w. Battery) |
7 |
32(w. Battery) |
11 |
33(w. Battery) |
12 |
ENVIRON
MENT |
Operating Temperature |
0~40 Degrees Centigrade, 20~90% relative humidity (non-condensing) |
Noise Level |
<45dB @ 1 Meter |
<45dB @ 1 Meter |
<50dB @ 1 Meter |
| INTERFACE |
Smart RS-232 |
Windows 98/NT/2000/XP/2003/ME, Linux, Sun Solaris, IBM Aix, Compaq True64, SGI IRIX, FreeBSD, HP-UX, amd MAC |
SNMP (option) |
Power management from SNMP manager and web browser |
UG1K (XL), UG2K (XL) & UG3K (XL) for long Backup time model with additional Battery Packs are available, please consult local distributors.
|
|
|